Which Notes matter most for exam-style questions?
Most Notes are background you will never need under time pressure. The short list below is ours, built from the Section 2 objectives rather than from any official ranking.
| Note | Where | What it gives you | Objective |
| A-1.4.1.2.(1) Defined Terms | Division A, pp. 1-20 to 1-25 | Plain-language notes on terms such as exit, fire separation, flight, grade, public corridor and suite | 5.1, 5.2 |
| A-1.2.1.1.(1)(b) | Division A, p. 1-18 | The "as well as" test for alternative solutions | 5.4 |
| A-3 Application of Part 3 | Division B, pp. 3-225 to 3-226 | Discretion for unusual buildings and the firefighting assumptions behind Part 3 | 5.2 |
| A-3.1.2.1.(1) | Division B, pp. 3-226 to 3-229 | Examples of buildings in every major occupancy Group and Division | 5.2.1 |
| A-3.2.3. and A-3.2.3.1.(4) | Division B, p. 3-236 | Limiting distance versus separation between buildings, and how Sentences (3) and (4) work together | 5.2.2 |
| A-3.8. | Division B, p. 3-266 | Barrier-free design principles and four basic space dimensions | 5.2.4 |
| A-9.25.1.1.(2) | Volume 2, p. 9-584 | The difference between a vapour barrier and an air barrier | 5.3.4 |
| A-2.3.1. | Division C, p. 2-8 | Why alternative-solution documentation is kept | 5.4.4 |
Occupancy examples: A-3.1.2.1.(1)
Table 3.1.2.1. (p. 3-2) describes each Group and Division in a single line; the Note lists real building types under each one. Watch the pairs that make good distractors: television studios admitting a viewing audience are Group A, Division 1, while those that do not admit one are Group F, Division 2. Police stations with detention quarters are Group B, Division 1, and those without are Group D. Dental and medical offices are Group D. Laboratories appear under both Group F, Division 2 and Group F, Division 3, so the hazard decides.
Defined terms: A-1.4.1.2.(1)
The defined-terms Note explains the words examiners like to test. On p. 1-22 it says a fire separation is not always required to have a fire-resistance rating but should still act as a barrier to the spread of smoke and fire; where sprinklers allow the rating to be waived, the separation must stay in place as a smoke barrier until the sprinklers actuate. The exit Note confirms that exits include doors or doorways leading directly into an exit stair or directly outside.
Spatial separation and barrier-free design
Note A-3 explains that 10 to 30 minutes usually pass between the outbreak of fire in an unsprinklered building and high radiation levels, which is the window spatial separation is designed around. Note A-3.2.3. explains why limiting distance is measured to the property line rather than to the neighbouring building. Note A-3.2.3.1.(4) says Sentence (3) is applied first, to set the wall's rating, construction and cladding, before Sentence (4) refines the opening percentage. Our spatial separation worked example runs the full calculation.
Note A-3.8. lists four basic accessibility dimensions: a clear floor space of at least 800 mm by 1 350 mm, a 1 000 mm clear width for a 90° turn, a 2 100 mm diameter for a 180° turn in one motion and a 1 700 mm diameter for a 180° turn in multiple motions. Our post on barrier-free design in NBC Section 3.8 covers the numbers in the requirements themselves.
Part 9 envelope: A-9.25.1.1.(2)
A vapour barrier restricts water vapour moving because of vapour pressure differences, while an air barrier restricts air moving because of air pressure differences. A vapour barrier does not have to be continuous or sealed to do its job, but an air barrier must be continuous and fully sealed.